Description
YHCoat-900 UV-resistant elastic water-based liquid applied coating is prepared from special emulsion,high-quality fillers, and functional additives.
Specifications
| Item | Description |
|---|---|
| Packaging | 4kg pail / 20 kg pail |
| Composition | VAE emulsion |
| Shelf Life | 12 months from the date of production |
| Density | ~1.7g/l |
| Product Color | White / Grey |
| Description | Test Methods | Values |
|---|---|---|
| Tensile Strength | ASTM D412 | 2.86 MPa |
| Elongation at Break | ASTMD412 | 734% |
| Tensile Bond Strength | EN1542 | 1.30 MPa |
| UV Exposure (Xenon Arc Lamps) -Exposure for 720 hours | BS ENISO 16474 | No visual change was observed |
| Ambient Air Temperature | +5℃min. / +35℃ max. | |
| Substrate Temperature | +5 °C min. / +35 °C max. | |
| Substrate Moisture Content | ≤ 4% | |
| Waiting Time/Over coating | Minimum 2-3 hours at +30°C | Maximum ~1 day at +30° |
| Applied Product Ready for Use | ~72 hours at +30°C | |
| Consumption | 0.6 kg/㎡/coat | |
Surface Preparation
Concrete roof:
Ensure substrates are solid, clean, dry and free from contaminants such as dirt, oil, grease, old paint and loose material.
Ensure substrates are solid, clean, dry and free from contaminants such as dirt, oil, grease, old paint and loose material.
Color steel roof:
Damaged base must be repaired and the foundation treatment must be carried out with a matching primer.
Damaged base must be repaired and the foundation treatment must be carried out with a matching primer.
Environmental requirements:
Do not attempt application if rain is imminent.
Do not attempt application if rain is imminent.
Application:
Apply using a roller, brush or airless spray. Stir gently until the mix is homogeneous. For the primer coat, dilute YHCoat-900 with 15-20% clean water. Once the primer
coat is dry to touch, apply a minimum of 2 undiluted layers of YHCoat-900. Please ensure the previous layer is completely dry before applying the next.
Detail node treatment:
Expansion joints, drainage pipes and other detail nodes must be reinforced, and the reinforced polyester cloth is embedded in the coating in the way of “one cloth and two coatings”, so that the waterproof coating can fully saturate the carcass layer, and there shall be no wrinkles and warping.
Cleaning of tools:
Clean all tools and application equipment with water immediately after use. Hardened material can only be removed mechanically.
Features & Benefits
· High strength and high elasticity.
· Abrasion resistance.
· UV stability.
· Suitable for foot traffic.
· Easy to apply.
· Water based and non-toxic.
Scope of Application
· It is suitable fofor waterproof treatment of outdoor new and old concrete roofs, terraces, gutters, balconies, and other directly exposed parts.
· It is also suitable for the waterproof treatment of colorsteel roofs.
· Roofs with numerous details such as penetration drains and complex geometry.
· External walls.